ACQUISITION

Any protocol using a serial port will be available for serial devices which are Windows-compatible, such as multi-port boards [RS232C, RS422, RS485] or serial to Ethernet products.

ACQUISITION BY OPC SERVER

If the “SUPPORT” column  indicates “OPC Server”, you must acquire an appropriate OPC Server, not supplied with TOPKAPI.

OPC SERVER

TOPKAPI can be used as an OPC Server for each of the protocols listed hereafter. Regarding protocols for which “OPC Server” is mentioned in the “SUPPORT” column, this generally has no interest (except in special cases) as we otherwise have an OPC Server. For protocols with time-stamped data, TOPKAPI provides built-in modem management and historical data storage in any SQL compliant DBMS (Oracle, SQL Server, MySQL, PostgreSQL, etc.).

GATEWAY FUNCTION

TOPKAPI can be used as Gateway between several systems using distinct protocols.

The information below is applicable for the supply of the current TOPKAPI version. A version update may be required when adding a new protocol driver to an old TOPKAPI version, for technical or support reasons.

Languages: Engl for English, Sp for Spanish, Fr for French.

In Spanish, if this language is not available, the English driver is installed, but it is also possible to install manually the French version of the driver.

Depending on requirements, new protocols can be translated.

N.B. : All the protocols with real-time and time-stamped data, without intermediary front end with a modem management, need a modem management library.

PROTOCOLS
SUPPORT
Time- StampedSupport(1) 

 

Language
OBSERVATIONS
ABB Aquamaster SMS via GSM Modem Engl/Sp/Fr
ACT’L See EWON
ADCON OPC Server Engl/Fr

OPC Server provided by ADCON

ALLEN BRADLEY All protocols OPC Server Engl/Fr Contact Allen Bradley or OPCserver providers.
DF1, DH485, DH, DH+, console plug OPC Server orWOODHEAD-APPLICOM card(4) Engl/Sp/Fr Please contact WOODHEAD-APPLICOM.KF2 adapter required for DH+
Modbus, Modbus TCP TOPKAPI direct driver Engl/Fr Many providers of PLC communication cards (Allen Bradley, Prosoft) or gateways.
AMPHITEC Serial port Fr
AQUACOM Serial port or modem Fr/Eng See ITT FLYGT
ARITECH – MPI 232 (3) Serial port Fr CD 150 Units
ASI (AS-i) Specialized cards(4) Fr/Eng OPC Server requested, to be provided with the board
OPC Server or Gateway Engl/Fr Gateway AS-I to Modbus, Modbus Plus, Profibus DP, Interbus, DeviceNet, CANopen, CANrho (Bosch), CC-Link, LON, Modbus, TCP
BACNET TOPKAPI direct driver Engl/Fr Ethernet port, serial connection via router.
BAELZ Serial port or Modem Engl/Fr Jbus + specific layer fort time-stamp processing
BATIBUS WOODHEAD-APPLICOM card (5) Engl/Sp/Fr
BERIS (DATAM) Serial port Fr
BOBITECNIC Standard port + Modem Fr/Sp
BOSCH D6600 Serial port Fr Front End Equipment D6600
CD 150 ARITECH See ARITECH
CESA (3) Frontal Fr Frontal PE1200 – Please contact us
CR2M ALNAEE Standard port + Modem Fr
CR2M SAB600 / SAB6000 Standard port + Modem Fr
DATALOGGER IT File Protocol Fr Please contact us
DATAM FLUTEC
TM 16000  XC
(F4 Front End)
Serial port + F4 Front End Fr
DATBUS2 (DATAM – FLUTEC / ARCANTE / APILOG) Standard port + Modem Fr
DDE Soft Engl/Fr All servers (2)
DEF (NOVA, ALTARES, ANTARES) Serial port or Ethernet TCP/IP port Engl/Sp/Fr Fire Detection System Units (FDSU) & Fire Safety Controller Units (FSCU). Preset objects FD & SAD, import, AUTOCAD links:Please contact us for more details.
DNP 3.0 Native TOPKAPI Driver Engl/Fr
ETHWAY, FIPWAY, MAPWAY Specialized cards(4) Engl/Sp/Fr Windows 98/NT/2000/XP ProLibrairie YCCFPWPCV1 (Fipway) or YCCETHPCV1 (Ethway) required
WOODHEAD-APPLICOM card (5) Engl/Sp/Fr Ethway, Fipway
Specialized cards(4) Engl/Sp/Fr Only with Win 95/98, not WinNT: possible connection with the SCHNEIDER basic drivers, delivered with the Fipway/Ethway card, using the TOPKAPI 16 bits driver working in the compatibility mode.
ETIC Standard port + Modem Fr
EWON TCP/IP or Standard port modem Engl/Fr
EXEMYS Standard port + Modem Engl/Fr
GE – FANUC and CEGELEC SNP-X WOODHEAD-APPLICOM card (5) Engl/Sp/Fr
GE – FANUC Series 90-30 and 90-70 SRTP WOODHEAD-APPLICOM card (5) Engl/Sp/Fr
GERRIS – SAPPEL   See WAGAMET Ortomat
HYDREKA Eurolog (3) Standard port + Modem  
Multilog / Octopus LS SMS via GSM Modem Engl/Sp/Fr (6)
Octopus Standard port + Modem
Permalog+ / AMR GPRS via FTP Server Fr

Leak pre locator. Acquisition viaRadio-Tech Hub.

IDEC IZUMI Serial port Engl
IDS ARCOS 750,
IDS 650/850
 

See IEC 60870-5-101

and IEC 60870-5-104

IEC 60870-5-101 Serial port Engl/Fr
Serial port + Modem Engl/Fr Modem link is not supported by all devices which are IEC 60870-5-101 compliant.Please contact us to confirm compliance of the selected device with TOPKAPI.
IEC 60870-5-102
IEC 60870-5-103
Serial, modem, radio Engl/Fr OPC server developed by third party companies: please contact us.
IEC 60870-5-104 TCP-IP Engl/Fr GPRS compliant.
IJINUS SMS via GSM Modem Engl/Sp/Fr (6)
INT2500 AGBAR Serial port + modem Engl/Sp/Fr Modbus serial or modem, time stamped at the source (Areal format)
INTELLISONDE GPRS via FTP Server Fr Multi parameters sensors  for water quality management. SeeINTELLITECT WATER.
ISCO 2150 (TELEDYNE) Serial port + modem Fr
ITT FLYGT MACTEC (Aquacom) Standard port + modem Engl/Fr Self configuration by SOFTLINK wizard using the .ATF files
SRX 104 station  (Aquacom) (3) Serial port  
JBUS See MODBUS
JEL (3) Serial port  
JOHNSON CONTROL IM9100 Standard port + Modem Fr
OPTOMUX See OPTOMUX
KOSKAS Geoloc SMS via GSM Modem Engl/Sp/Fr (6)
LAC DDE server
 

LANDIS and STAEFA (RH 500, NITEL) Serial port
 

Fr
LON.LONWORKS OPC Server Engl/Fr GESYTEC’s EASYLON OPC Server successfully tested.Others: please contact us
MIRI (OVAL) AD2000 Serial port + Modem Engl/Fr Contacts :
Oval / Miri
OPC Server Engl/Fr
MITSUBISHI FX OPC Server Engl/Fr OPC Server Melsec FX
MODBUS JBUS Master Serial port Engl/Sp/Fr Time stamp processing : SEPAM 2000 format, or AREAL’s advanced formats. please contact us
Standard port + Modem Engl/Sp/Fr
MODBUS JBUS Slave Serial port Engl/Fr Can also be used for routing and / or communication gateway
MODBUS TCP-IP Master TCP-IP Engl/Sp/Fr Time stamp processing : SEPAM 2000 format, or AREAL’s advanced formats. please contact us
MODBUS TCP-IP Slave TCP-IP Engl/Fr Can also be used for routing and / or communication gateway
MODBUS PLUS Specialized cards(4) Fr/Sp
MPI 232 See ARITECH
NAPAC – NAPBUS Standard port + Modem Fr TBC type units.
Standard port + Modem or TCP-IP Network Fr XFLOW type units: Flowtel, Phoenix, Rio, etc.
NUGELEC Serial port Fr
OMRON SYSMACWAY / Serial port Fr
OPC Omron server Engl/Fr Please, contact OMRON for supported devices
OPC Depending on the server supplier Engl/Fr Please, consult us if needed
OPTOMUX Serial port
 
Fr
OTIC FISHER DATALINK WOODHEAD-APPLICOM card(5) Engl/Sp/Fr
OTT DuoSens SMS via GSM Modem Engl/Sp/Fr Datalogger (6)
LogoSens SMS via GSM Modem Engl/Sp/Fr Datalogger (6)
PACSNET (3) PACS Radio modem Fr
PALMER Permanet SMS via GSM Modem Engl/Sp/Fr (6)
PERAX Standard port + Modem or Arlequin Front End Engl/Sp/Fr P200, P200x, P400xi, P16XT
PERAX SMS (P16XT) SMS via GSM Modem Engl/Sp/Fr (6)
PRIMAYER Phocus SMS via GSM Modem Engl/Sp/Fr (6)
Primelog Serial port + Modem Engl/Sp/Fr
Xilog SMS via GSM Modem Engl/Sp/Fr (6)
PROFIBUS / SINEC L2 WOODHEAD-APPLICOM card (5) Engl/Sp/Fr
OPC Server Engl/Fr OPC Server SCOUT.Please contact SIEMENS for protocols handled and hardware required.
RADCOM – Multilog Standard port + Modem (PSTN) Fr/Sp
SMS via GSM Modem Engl/Sp/Fr (6)
ROCKWELL See ALLEN BRADLEY
SAC (3) Serial port
 SAE-IT See IEC 60870
SATCHWELL DDE MICRONET Server Fr Local or remote via modem, no time stamped data.
SAUTER BACNET Ethernet IP   Engl/Fr
NOVANET (EY3600, MODULO2) Serial port Fr Serial (local)/modem (remote) link to Router/Routel unit for fieldbus NOVANET
Others   See BACNET or LON
SBUS – SAIA WOODHEAD-APPLICOM card(5) Engl/Sp/Fr
SCHNEIDER ELECTRIC JBUS – MODBUS See MODBUS
MODBUS IP See MODBUS TCP-IP
 SCHNEIDER ELECTRIC
NAPBUS, XFLOW
  See NAPAC
SCHNEIDER ELECTRIC W@DE Standard Port + Modem Engl/Fr W@DE W320, W330, …
SCHNEIDER ELECTRIC(TELEMECANIQUE)
ETHWAY, FIPWAY, MAPWAY
Specialized cards(4) Engl/Sp/Fr Windows 98/NT/2000/XP ProLibrairie YCCFPWPCV1 (Fipway) or YCCETHPCV1 (Ethway) required
WOODHEAD-APPLICOM card (5) Engl/Sp/Fr Ethway, Fipway
Specialized cards(3) (4) Engl/Sp/Fr Only with Win 95/98, except WinNT: possible connection with the SCHNEIDER ELECTRIC basic drivers, delivered with the Fipway/Ethway card, using the TOPKAPI 16 bits driver working in the compatibility mode.
OPC Server Engl/Fr Server OFS of SCHNEIDER ELECTRIC. To consult SCHNEIDER ELECTRIC according to your network and your equipment
SCHNEIDER ELECTRIC
TCP/IP (See Modbus-Jbus Master in TCP-IP too)
Specialized cards(4) Engl/Sp/Fr IPC UNI-TE library required
WOODHEAD-APPLICOM card (5) Engl/Sp/Fr
SCHNEIDER ELECTRIC
ISAWAY
Specialized cards(4) Engl/Sp/Fr UNI-TE/ISAWAY PCUNI-TE library needed
SCHNEIDER ELECTRIC
UNITELWAY Slave
Serial port Engl/Sp/Fr The driver can be used in slave mode only.
SCHNEIDER ELECTRIC
UNITELWAY Master or Slave
WOODHEAD-APPLICOM card (5) Engl/Sp/Fr
SCHNEIDER ELECTRIC UNITY-PRO Engl/Fr According to the protocol in use (see above), most frequently SCHNEIDER ELECTRIC’s OFS server (OPC).
SDG (Lyonnaise des Eaux) TCP/IP Network card Engl/Fr
SEBA Hydrometrie Standard port + Modem Sp/Fr MDS5 devices
SECURITE COMMUNICATION (PE1200) (3) Front end Fr
 SERIEE EROS20 Front end PC Fr
SEVME (Sevbus) Standard port + Modem Engl/Sp/Fr
SEWERIN Sepem SMS via GSM Modem Engl/Sp/Fr Leak prelocator.(6)
3964R WOODHEAD-APPLICOM card (5) Engl/Sp/Fr
Serial port by the WOODHEAD-APPLICOM server SPWIN Engl/Fr (3)
AS511(S5) WOODHEAD-APPLICOM card (5) Engl/Sp/Fr
Building Technologies CERBERUS Serial port or Ethernet TCP/IP port Engl/Sp/Fr Via Modbus gateway provided by Siemens-Cerberus.Fire Detection System Units (FDSU) & Fire Safety Controller Units (FSCU). Preset objects FD & SAD, import, AUTOCAD links:please contact us for more details.
Building Technologies LANDIS and STAEFA (RH500, NIDES, NITEL) Serial port + modem Fr NRK16, NRK9, NRV (A, B, C, D), NRD.Details
INDUSTRIAL ETHERNET OPC Server SCOUT Engl/Fr

Please contact SIEMENS

OPC Server WOODHEAD-APPLICOM (5) Engl/Fr

WOODHEAD-APPLICOM card not required (use of standard network adapter)

Please contact WOODHEAD-APPLICOM

SINEC H1 WOODHEAD-APPLICOM card (5) Engl/Sp/Fr
SINEC L1 DDE Server (2) orWOODHEAD-APPLICOM card (5) Engl/Fr
PROFIBUS / SINEC L2 WOODHEAD-APPLICOM card (5) Engl/Sp/Fr
OPC Server Engl/Fr

OPC Server SCOUT

Please contact SIEMENS for protocols handled and hardware required.

SNMP Manager Ethernet /
TCP-IP
Engl/Fr Used for data acquisition
SNMP Agent Ethernet /
TCP-IP
Engl/Fr Used to make data available to SNMP manager.Can be used as protocol gateway.
SNP -X (GE – Fanuc and CEGELEC) WOODHEAD-APPLICOM card(5) Engl/Sp/Fr
SOFREL LACBUS
(S500, LS10, LS42)
Standard port + Modem Engl/Sp/Fr Support of event-driven communication
TCP-IP / GPRS Engl/Sp/Fr Support of event-driven communication
FR1000 Front End Engl/Sp/Fr
SOFREL SOFBUS
(S10, S15, S40, S500, LS10, LS42)
Standard port + Modem Engl/Sp/Fr Support of event-driven communication
TCP-IP / GPRS Engl/Sp/Fr Support of event-driven communication
 CS100 / FR1000 Front End Engl/Sp/Fr
SOFREL SMS (CELLBOX, LS10, LS42) SMS via GSM Modem Engl/Sp/Fr (6)
SRTP (GE – Fanuc Serie 90-30 and 90-70) WOODHEAD-APPLICOM card(5) Engl/Sp/Fr
STRATEL Serial port + Modem Fr Please contact us for hardware required.
SUCOMA (KLÖCKNER-MOELLER) (3) Serial port
WOODHEAD-APPLICOM card (5) Engl/Sp/Fr
SULZER (SICOS) Serial port via Front end: please contact us.
SYSMACWAY (OMRON) Serial port Fr
WOODHEAD-APPLICOM card (5) Engl/Sp/Fr
TBOX (Semaphore – Technotrade) Standard port + Modem Engl/Sp/Fr
TECHNOLOG CELLO

 SMS via GSM Modem

Engl/Sp/Fr (6)
Newlog

Standard port + Modem

Fr
TEXAS INSTRUMENTS TI-DIR (TI505) WOODHEAD-APPLICOM card(5) Engl/Sp/Fr
TRS II (WIT, AQUAVEIL) Standard port + Modem Engl/Sp/Fr
MONET/Aquaveil II Front end Engl/Sp/Fr
UNITELWAY Master or Slave See SCHNEIDER ELECTRICabove
WAGAMET Ortomat SMS via GSM Modem Engl/Sp/Fr (6)
WEBDYN GPRS via FTP server Fr WebdynTIC gateway use to collect electrical counting data.

Many OPC Servers or DDE servers are also available, and AREAL develops protocols according to your requirements.

Version:

32 means that the protocol is fully compatible.

16 means that a thunk layer has been developed ; the protocol 16 bits works with Windows 95/98 and Windows NT. Port numbers available for 16 bits drivers are 1 to 10 (Windows 9x) and 1 to 9 (Windows NT).